MQ-6 Liquefied Isobutane Propane Sensor

SKU: FA3059-0
Sensor Model

MQ-6 (SnO₂ semiconductor)

Target Gases

LPG, Isobutane, Propane, Butane

Detection Range

300 – 10,000 ppm (Propane/Butane/LPG)

Operating Voltage

5V DC

Heater Voltage

5.0V ± 0.2V AC/DC

Heater Power Consumption

≤ 900mW

Output Type

Analog (AO) + Digital (DO/TTL)

Preheat Time

Not less than 48 hours

The MQ-6 Liquefied Isobutane Propane Sensor is a low-cost, highly sensitive semiconductor gas detection module designed for monitoring liquefied petroleum gas (LPG), isobutane, propane, and butane in domestic, industrial, and portable gas detection applications. Built around the MQ-6 sensor with a tin dioxide (SnO₂) sensing layer, this module offers high sensitivity to LPG-family gases while maintaining good resistance to interference from alcohol, cooking fumes, and smoke. It is an ideal solution for household gas leak alarms, industrial combustible gas detectors, and portable gas detection instruments.

At the heart of the module is the MQ-6 sensor element, whose conductivity increases as the concentration of target gases rises. In clean air, the sensor exhibits low conductivity; when exposed to LPG, isobutane, or propane, its resistance drops, producing a measurable change in output. The module provides two independent outputs: an analog output (AO) that varies continuously with gas concentration for trend monitoring, and a digital output (DO) that switches when the concentration exceeds a user-adjustable threshold set by the onboard potentiometer. This dual-output design makes it suitable for both quantitative trend analysis and simple threshold-based alarm triggering.

The module operates from 5V DC with a typical current consumption of approximately 150mA. It is compatible with Arduino, ESP32, and other 5V microcontrollers; Raspberry Pi users require an external ADC. The board features a compact 32 × 20 × 22mm form factor and an onboard LED indicator that provides visual feedback for power and digital output status.

Important Note: The MQ-6 requires a significant preheat time for stable operation. The sensor should be powered on for not less than 48 hours in clean air before initial calibration. After each power-up, allow at least 20 seconds to 2 minutes for the heater to stabilize. The sensor is not a calibrated industrial-grade detector and should not be used as a sole life-safety device. Its sensitivity degrades over time, and periodic replacement is recommended for critical applications. The sensor surface becomes hot during operation — avoid touching it. The module is not waterproof and should be kept dry. Avoid exposure to organic silicon vapors, high concentrations of corrosive gases, or alkali metal salts, which can permanently damage the sensing element.

Whether you are building a home gas leak alarm, an industrial LPG detector, or an educational sensor project, the MQ-6 module provides a reliable, affordable solution for liquefied gas and propane detection.

Features

  • MQ-6 SnO₂ semiconductor sensor — High sensitivity to LPG, isobutane, propane, and butane

  • Good anti-interference — Resistant to alcohol, cooking fumes, and smoke interference

  • Dual output — Analog (AO) for concentration trends, Digital (DO) for threshold alarms

  • Adjustable threshold — Onboard potentiometer sets the digital output trigger point

  • Wide detection range — 300–10,000 ppm for propane, butane, and LPG

  • 5V operation — Compatible with Arduino, ESP32, and other 5V microcontrollers

  • LED indicators — Power and digital output status feedback

  • Compact form factor — 32 × 20mm PCB for easy integration

  • Fast response and recovery — Quick detection of gas concentration changes

  • Wide application range — Household gas alarms, industrial detectors, portable instruments

Technical Specifications 

# Parameter Specification
1 Sensor Model MQ-6 (SnO₂ semiconductor)
2 Target Gases LPG, Isobutane, Propane, Butane
3 Detection Range 300 – 10,000 ppm (Propane/Butane/LPG)
4 Operating Voltage 5V DC
5 Heater Voltage 5.0V ± 0.2V AC/DC
6 Heater Power Consumption ≤ 900mW
7 Output Type Analog (AO) + Digital (DO/TTL)
8 Preheat Time Not less than 48 hours

Usage

Getting Started

  1. Connect power — Connect VCC to 5V and GND to ground. The onboard power LED should light up.

  2. Connect outputs — Connect AO to an analog input on your microcontroller (e.g., A0 on Arduino) and DO to a digital input if threshold detection is needed.

  3. Preheat — Allow the sensor to warm up. For first-time use, power it in clean air for not less than 48 hours for best accuracy. For normal use, wait at least 20 seconds to 2 minutes before taking readings.

  4. Calibrate (recommended) — In clean air, note the analog reading. Adjust the onboard potentiometer so the DO output switches just above this baseline.

  5. Read data — Use analogRead() for concentration trends, or digitalRead() for threshold-based alarms. Note that the digital output is typically LOW when gas is detected (active-low logic).

  6. Implement control logic — Trigger buzzers, valves, or notifications when the sensor value exceeds your defined threshold.

Pin Connections

Module Pin Function
VCC Power (5V DC)
GND Ground
DO Digital output (LOW when threshold exceeded)
AO Analog output (voltage changes with gas concentration)

Example Arduino Code (Basic Reading)

cpp
#define MQ6_AO A0
#define MQ6_DO 8

void setup() {
  Serial.begin(9600);
  pinMode(MQ6_DO, INPUT_PULLUP);
}

void loop() {
  int analogValue = analogRead(MQ6_AO);
  int digitalState = digitalRead(MQ6_DO);

  Serial.print("Gas Level: ");
  Serial.print(analogValue);
  Serial.print(" | Alarm: ");
  Serial.println(digitalState == LOW ? "TRIGGERED" : "Normal");

  delay(1000);
}

Typical Applications

  • Household gas leak alarms — Detect LPG leaks from stoves, cylinders, and pipelines

  • Industrial combustible gas detectors — Monitor LPG and propane in workshops and facilities

  • Portable gas detection instruments — Handheld detectors for field work

  • Educational STEM projects — Teaching analog sensing, gas detection, and calibration principles

Notes for Business Buyers

  • Preheat is essential — The 48-hour initial burn-in is critical for stable readings; factor this into production testing timelines

  • Not a precision instrument — MQ sensors provide relative trend data, not exact ppm readings for specific gases

  • Sensor lifespan — Specified for long life under proper conditions, but practical lifespan depends on exposure to contaminants

  • Suitable for bulk purchasing — Ideal for gas alarm manufacturers, educational kit suppliers, and industrial safety product developers

Q: What is the MQ-6 sensor used for?

It is a gas sensor for detecting LPG, isobutane, propane, and butane in household gas leak alarms, industrial combustible gas detectors, and portable gas detection instruments.

Q: What is the difference between the analog and digital outputs?

AO provides a continuous voltage that changes with gas concentration for trend monitoring. DO switches LOW when the concentration exceeds the onboard potentiometer threshold, ideal for simple alarms.

Q: Why does the sensor need a long preheat time?

The SnO₂ sensing element requires heating to reach stable operating temperature. The datasheet specifies a preheat time of not less than 48 hours for reliable operation.

Q: Can I measure exact ppm with this sensor?

Not accurately without calibration. The MQ-6 is non-selective and provides relative trends. For quantitative measurement, you need calibration curves and cross-sensitivity compensation.

Q: What voltage does the module require?

It operates from 5V DC with approximately 150mA current consumption.

Q: Does the sensor respond to other gases?

The MQ-6 has high sensitivity to propane, butane, and LPG, with good anti-interference to alcohol and smoke. However, it may still respond to other combustible gases.

Q: Is the sensor safe to touch?

No. The sensor surface becomes hot during operation due to the internal heater. Avoid touching it.

Q: Can I use this module with a Raspberry Pi?

Yes, but the Pi lacks a built-in ADC. Use an external ADC (e.g., MCP3008) to read the AO output.

Q: How long does the sensor last?

The sensor is specified for long life under proper conditions, but practical lifespan depends on exposure to contaminants.

Q: Can I purchase in bulk for a product development project?

Yes. This module is suitable for bulk purchasing by gas alarm manufacturers, educational kit suppliers, and industrial safety product developers.